PCD8.P5     PG5 1.4.300 programming tool

Click with the right mouse button on the relevant icon and select "save target as..." to download a file. Use the left mouse button to view it.
 

Documentation

MB Files
Catalog System Catalog Infrastructure Automation 26/215 D9, E9, F9, I9 35    
Technical Information PG5 Programming Tool 26/362 D7, E7, F7, I7, RU1, SV4 0.8  
Technical Information This document is obsolete and therefore not up to date HMI-Editor and PLC-based terminals 26/430 D4, E4, F4, I4, SV1,    2.4  
Manual HMI-Editor 26-768, D9, E9, F9, I6, ES1 12  
Manual Quickstart HMI-Editor 26-768, D, E, F, I 0.4  
Manual Icon-Editor 26-832, D2, E2, F2 0.8
Technical Information This document is obsolete and therefore not up to dateSaia® S-Web-Editor 26/453 D3, E3, F3, CS1 0.8
Technical Information Standard FBoxes 26/367 D2, E2, F2, I2, RU1 0.3
Technical Information This document is obsolete and therefore not up to date HeaVAC Library FBoxes 26/398, D2, E2, F2, I2 0.6
Technical Information Modem FBoxes 26/368 D2, E2, F2, I2 1.3    
System Information Saia®FBox-Builder 26/422, DE3, EN3, FR3, IT3 2.5  
Manual Saia®FBox-Builder (Limited Version) 26/831  D6, E6, F6, I2 6.2  
Manual Saia®FBox-Builder (Advanced Version) 26/387  E1 1.7  
Manual UpDownLoader E, I 0.7  
Additional Documentation (Manuals, Workshops) can be found on the Controls Suite CD
   

Controls Suite CD, containing PG5 1.4.300 demonstration version for Windows XP or 2000

MB Files
This version allows to use the full functionality of PG5 and the HMI-Editor for 90 days after the installation. For an installation on Windows Vista, please refer to the "Technical reports" section below.
Download PG5 V 1.4.300 package as on CD 438
Procedure for updating the PG5 1.4 from an earlier version of PG5 1.4.xxx:
  • download version V1.4.300 from this page
  • uninstall the previous version
  • install the version V1.4.300 (the key file that was distributed with previous 1.4.xxx version can still be used)
Release notes PG5 SP 1.4.300 0.1   
Release notes Web Editor 5.13.00 0.7   
Patches for PG5 V 1.4.300 (not contained in package above)

Description of the modifications contained in the PG5 1.4.300 patches


0.2  .txt

 
 

Patches

MB Files
Patch 15 (version 1) for PG5 1.4.300
This patch applies to PG5 1.4.300 and will also update the below listed FBox libraries.
A patch 15 has been availabe at this point until may 12th. Due to a problem of the S-Net Configurator in this patch, it has been removed from this site! Please download the current version and install it again.
22.3  
Main corrections in PG5
  • In the Device Configurator a correct subnet mask was idicated as invalid
  • The analog outputs of a PCD3.M2130V6 could not be scaled correctly (German language only).
  • When using the Device Configurator port 3 of a PCD3.M5340 could not be used as Master Gateway
  • Help file for the Device Configurator added/improved
  • No error message if fails to write backup file. e.g. when saving a file in the Common Files directory.
  • Patch installer works also for W2k
     
New features in PG5
  • Support of PCD3 Compact with extension modules.
     

Main modifications in FBox libraries

  • S-Fup standard FBox library 2.6.150
    - Initialization of FBoxes "High" and "Low" are improved during start-up (XOB16)
    - Support for PCD4.U100
  • S-Fup analog FBox library 2.6.100:
    - Output of PCD2/3.W525 modules did not always work, see FAQ 101204.
  • Heavac library 2.5.316
    - New FBoxes "Fan optimizer PI" and "Fan max Position"
    - New option for "Command FIFO/FILO" FBox; option FILO added
    - New FBox "Dead range with delay", FBox which limits the frequency of value changes
    - New FBox "Easter days" to detect catholic holidays based on Easter
    - Improvements for FBoxes Conversion 2 points and 20 points
    - Translated help for new FBoxes
    - Support for PCD4.U100
  • Belimo MP Bus FBox library 2.5.305:
    - Support of PCD2/3.F281 modules
    - Avoids possible conflict with global symbol with name "Error"
  • FBox library for File System 2.5.307
    - New FBoxes "Write big DB/Text" and "Read big DB/Text"
    - Record and backup interval bigger than 6:55:35 caused assembler error.
  • EIB Library 2.5.312
    - EIB Net/IP driver: multi-telegram buffer implemented.
    - FBox "EIB RCV Time+Date" improved
  • Modbus(für PCD3 and PCD2.M5xx0 FW 1.10.16 and later), version 1.0.017
    - New option to define an offset for the client FBoxes
    - Sometimes an error was indicated even if no error was present, see FAQ 101295
  • Modem FBox library version 2.5.304
    - The calling number can now have the "+" sign for international numbering system (replaces the '!' modem command).
    - The "Init" input of the FBox "Modem Driver" is now dynamized.
  • LON FBox library 2.5.142
    - Data decoding corrected in FBoxes "Rcv Binary" and "Value Rcv"
    - Value convertions improved in FBoxes "Send Heavac Status" and "Rcv Heavac Status"
     

Remarks

  • Please note that the FBox following FBox libraries are not contained in this patch; please update them manually
    - DDC Suite
    - Room controller PCD7.L6
    - HDLog (to File) FBoxes
    - S-Web Alarming FBoxes
  • It is no longer necessary launching additional files for installing the patch (as it has been the case unitl patch 9).

 

Web Editor 5.14.30 package for PG5 1.4.300

MB Files
Web-Editor Package (not included in the PG5 Controls Suite CD)
This package contains the latest Web Editor Package which consists of the following files:
  • Setup for S-Web Editor version 5.14.30
  • FBoxes for Trending to DBs or to the file system (HDLog SP2.1.040)
  • FBoxes for the File system (FileSystem 2.5.307)
  • FBoxes for the Alarming macros of the S-Web Editor

Install the files by launching the "Setup Web Editor V14.exe" from the WebEditor folder as well as the two executables in the folder "FBoxes".
Please note that for the HDLog to File functionality the firmware 1.10.51 is required for PCD2.M5 and PCD3 systems.
For more information regarding the new features, please refer to FAQ 101272.

22.4  

 

PG5 V 1.4.300 parts

MB Files
S-Online tools (included in the PG5 Controls Suite CD)
For customers who only need up- or downloading a built PG5 project to a PCD. The S-Online tools are a subset of the PG5 installation and does not require a license. The S-Online tools consist of:
  • Online Configurator (stand-alone configurator for Saia PCD hardware)
  • Command line Up/Downloader (tool for up- and downloading PCD program files)
  • Data Transfer Utility (tool for saving and loading a PCD Registers, Flags, Timers, etc. to/from text files)
Note that all these tools are part of PG5. In case PG5 is already installed, the installation of the S-Online tools won't have any effect.
10.1   
 

SComm Driver Update 1.4.321 for running PG5 V 1.4.300 on 64 Bit systems

MB Files
This SComm Driver Update will update the USB driver and the S-Bus driver from your PG5 1.4.300 installation. In order to install it, please execute the following steps:
  • Install PG5 1.4.300
  • Apply the last patch from this page
  • Execute the PG5_1_4_SCommUpdate_1_4_321.exe
    The SCommUpdate must be installed after the patch!
Note that this Update is also required in case you are running PG5 2.0.153 or later!
5.8   
 

Technical reports

MB Files
Step by step installation guide for PG5 1.4.300 on MS Windows 7 and Vista (32 and 64 bit),
version 3 of the document
3.6  
Compatibility Information PG5 1.4 & MS Windows 7 (March 2011) 0.1  
Compatibility Information PG5 1.4 & MS Windows Vista 0.1  
Moving projects from PG3 to PG5, example for H-modules 0.3   
 

Good to know

MB Files
PG5 1.0, 1.1, 1.2 and 1.3 are obsolete, we recommend to use the version 2.0 or 1.4.300 with the latest patch applied
Windows 95, 98, ME and NT are no longer supported by PG5 1.4.xxx or later. PG5 1.3.xxx was the last version to support these outdated operating systems.
Windows 2000: What to do if PG5 cannot be used by normal users after the installation by a super user 0.4  
     

FAQ Manager

Please refer to the FAQ Manager for frequently asked questions, hints and other useful information about our products
 

Please contact your local Saia Sales Company to get more information and/or the current version of this product.

Link to contact finder of saia-pcd.com
 

Additional information for Sales Companies

Change to the restricted area